Filter Results By:

Products

Applications

Manufacturers

High Voltage

electric power transmission is > 35,000 volts and for safety AC > 1000 and DC > 1,500. AKA: HV

See Also: High Voltage Switching, High Voltage Meters, High Voltage Detectors, High Voltage Programmable Power Supplies, HV


Showing results: 1966 - 1980 of 2470 items found.

  • Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel

    40-201-004 - Pickering Interfaces Ltd.

    This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.

  • Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel

    40-201-008 - Pickering Interfaces Ltd.

    This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.

  • Transceiver Module

    Mornsun Guangzhou Science & Technology

    MORNSUN transceiver modules include integrated high efficiency CAN, RS485, RS232 isolated transceiver module, protocol conversion module and serial port to ethernet transceiver module. These industrial bus transceiver with DIP, SMD, SOIC and DFN optional packages features compact size, surge and ESD bus protection, a maximum isolation voltage up to 5,000 VDC and a wide operating temperature range of -40°C to 85°C, even up to 105°C, etc. Coupled with the use of IC integrated technology,  the isolated transceiver module can easily be embedded in the user's end equipment, and achieve fully-functional bus network connectivity and data communication. Check out these isolated transceiver modules with a reasonable price along with high performance and we hope that they are an ideal fit for your application needs.

  • Multi-Channel Digital Power Meters

    66203/66204 - Chroma Systems Solutions, Inc.

    Voltage Range :15/30/60/150/300/600 VrmsCurrent Range :0.005/0.02/0.05/0.2/0.5/2/5/20 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bits Analog/Digital convertersHalf rack size, 4 input modules design (66204)Support different wiring configuration power measurement (1P2W/1P3W/3P3W/3P4W)Support external shunt and CT for higher current measurement application5 mA minimum current range & 0.1mW power resolutionMeets ENERGY STAR / IEC 62301 /ErP measurement requirementsAccumulated energy methods for unstable power measurementUser-define criteria provides automatic PASS/FAIL indicationsDual current shunt design provides high accuracy over a wide current rangeTHD and user-specify order distortion measurementInrush current and energy measurementVoltage/ Current harmonics measurement up to 50 orders

  • High Performance High Power DC Electronic Load

    IT8900 Series - I-TECH Electronic Co., Ltd

    IT8900 series of high performance high power dc electronic loads provide three voltage ranges 150V/600V/1200V. The power expands to 600kW by master-slave paralleling, and maintains stand-alone functions. 50kHz high speed measurement, six working modes, transient over-power loading capability, CV loop speed adjustment, Measurement function, 25kHz dynamic test and other multiple accurate testing functions make IT8900 series well-suited for types of high power applications. Built-in LAN/USB/RS232/GPIB interfaces are designed formany fields such as power supply, power battery, DC charging station, generators, military and aerospace etc.

  • Hall Effect Sensors

    Mors Smitt Group

    The transducers are based on compensating the magnetic field by a closed loop system. Ensure high accuracy of voltage and current measuring in railway traction or substation power equipment for protetion against power surges, overload, ground fault detection. Hall effect measurement to offer maximum protection in railway applications.

  • Dual Precision Power Amplifier

    VX4616 - VX Instruments GmbH

    2 galvanically isolated bipolar output channelsFrequency bandwidth up to 150 kHzOutputs are operating as inverting precision power amplifierOutputs are operating as programmable DC source (voltage or current)Outputs are programmable or adjustable via an external analog sourceAuto sensing featurePulse modulation with extremely high slew rate

  • Analogue (1kV below) Insulation Tester

    2132 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on low ohms : 3Ω & 500Ω.● Compact and lightweight.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test. ● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.

  • Analogue (1kV below) Insulation Tester

    1832 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on low ohms : 3Ω & 500Ω.● Compact and lightweight.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.

  • 600A Digital Clamp Meter

    7128C - Peaceful Thriving Enterprise Co Ltd

    This is an auto-ranging, high accuracy and stable hand held clamp meter to make electrical maintenance safe and easy. With special designed IC to support true RMS, the meter is available to measure AC/DC voltage to 600V, AC/DC current to 600A and resistance to 60MΩ; also having the capability to test diode, continuity, frequency and non contact voltage sensing. Sub switch included Function Select, Value Hold, Range Select, Relative Value Measurement, Inrush Current Indication, Hz/Duty Cycle, Illumination and Back-light.

  • Capacitor Leakage Current/IR Meter

    Chroma 11200 - Chroma Systems Solutions, Inc.

    The 11200 Capacitor Leakage Current / IR Meter is mainly used for electrolytic capacitor leakage current testing and aluminum-foil withstand voltage testing (EIAJ RC-2364A). The 11200 can also be used for active voltage checking or leakage current testing of absorber, Zener diode, and Neon lamp etc. With the standard RS232 interface, optional GPIB & Handler interfaces, high speed and stable measurement capabilities, the Chroma 11200 can be used for both component evaluation on the production line and for fundamental leakage current or IR testing for bench top applications.

  • Pulse Adapter

    CV30P650 - Frothingham Electronics Corporation

    The CV30 P650 test station is currently the highest voltage pulser in a series of exponential pulse generators that can be connected to our FEC200E tester. This gives you all the versatility of the proven FEC200 with the addition of high power exponential pulses. The CV30 P650 pulse adapter can produce a maximum current of 100A at up to 600V using exponential pulses up the 10/1000 waveform. The pulser is rated at 30KW from 300V to 650V. Voltage compliance at 100A is 600V. The station can also include all of the usual FEC200 tests in the same test program.

  • PXI Interface Module, AIT MIL-STD 1553

    M3406A - Keysight Technologies

    Interface to the LRU in avionics test solution Up to four channel MIL-STD-1553 bus interface with full error injection and detection Concurrent Bus Controller, multiple Remote Terminals (31), and Bus Monitor operation capabilities Data capture filtering, 100% bus recording, and physical bus replay Variable output voltage signal and software selectable bus coupling modes 10 high voltage (up to 30 V) programmable DIO lines PXI trigger generation on 1553 bus events

  • Multimeter Test Probes

    Parrot Invent

    Multimeter Test Probes, Voltmeter  test leads,with the Parrot™ Clip Invention provide precise,  HQ, accurate, reliable contacts and connections. Parrot™ Clips with HQ leads and banana plugs or other connectors are the best solution for DDM, analog multimeter for high voltage measurements as well as for high current measurements. Measurements with multimeter test probes require both:  Hands-on  direct point contact and grip on, Hands free removable connection.

  • Impulse Semiconductor High Current Integrated

    Transmission Line Pulse Test System - Impulse Semiconductor Inc.

    The Impulse Semiconductor High Current Transmission Line Pulse (TLP) test system is the tool of choice for extracting ESD parameters for transient protection devices in a package, or at wafer level. With accuracy better than 100 milliohms at 40 amps peak current, the Impulse high current TLP is specially tailored to the needs of today's ESD device designers who must accurately measure low values dynamic resistance irrespective of breakdown voltage.

Get Help